Diathermy is further prohibited because it may also damage the neurostimulation system components. Patients should be aware that during skydiving, the sudden jerking that occurs when the parachute opens may cause lead dislodgement or fractures, which may require surgery to repair or replace the lead. Keep the current paths from the electrosurgery device as far from the neurostimulation system as possible. During the 2000s about a dozen companies sold and manufactured SCS systems worldwide, including the "big three" (Boston Scientific, Abbott/St. Lasting Relief through our smallest system yet. Unilateral or bilateral stimulation of the ventral intermediate nucleus (VIM) of the thalamus for the management of disabling tremor. Some antitheft devices, such as those used at entrances or exits of department stores, libraries, and other public places, and airport security screening devices may affect stimulation. In the clinical experience with this device, patients have experienced few effects when moving from lying down to sitting up. We know that MRI scans are an important and trusted visualization tooland thats why weve designed our devices and technologies to fit as seamlessly as possible into this critical step in your diagnostic workflow. away from the generator and avoid placing any smart device in a pocket near the generator. Instruct patients to avoid scuba diving and entering hyperbaric chambers above 1.5 atmospheres absolute (ATA) because these activities might damage the neurostimulation system. Preventing infection. For information that supports the clinical use of this neurostimulation system, refer to the clinical summaries manual for spinal cord stimulation (SCS) systems (available online at medical.abbott/manuals). Explosive or flammable gasses. This includes oxygen-enriched environments such as hyperbaric chambers. Exposure to body fluids or saline. Before beginning a CT scan, the operator should use CT scout views to determine if implanted or externally worn electronic medical devices are present and if so, their location relative to the programmed scan range. The following additional considerations should be made for patients with diabetes: A pre-operative risk assessment should be performed for patients with diabetes who are at high risk for ischemic heart disease, those with autonomic neuropathy or renal failure, and patients with a Hemoglobin A1C (HbA1c) 8% (64 mmol/mol). To prevent unintended stimulation, do not modify the operating system in any way. Abbott's Proclaim XR Spinal Cord Stimulation System Now Offers Expanded MRI Compatibility in U.S. - New U.S. FDA-approved labeling lifts restrictions on 60-centimeter Octrode leads, which are implanted, electrically insulated wires that transmit electrical impulses to the target nerves Deep brain stimulation potentially has the following adverse effects: Possible surgical complications. Some models of this system are Magnetic Resonance (MR) Conditional, and patients with these devices may be scanned safely with magnetic resonance imaging (MRI) when the conditions for safe scanning are met. IPG disposal. Closely monitor patients for signs of infection, delayed wound healing, or cerebrospinal fluid (CSF) leakage as the severity of these complications may be greater in patients with diabetes. For complete MRI guidance, parameters and cautions for all Abbott neuromodulation systems, please see the product manual for each of our devices. For more information about MR Conditional products, visit the Abbott Medical product information page at neuromodulation.abbott/us/en/healthcare-professionals/mri-support.html. Some antitheft devices, such as those used at entrances or exits of department stores, libraries, and other public places, and airport security screening devices may affect stimulation. If lithotripsy must be used, do not focus the energy near the IPG. The use of components not approved for use by Abbott Medical with this system may result in damage to the system and increased risk to the patient. If any component of the implanted neurostimulation system, such as an IPG, lead, or extension, does not meet the requirements for an MR Conditional system, do not perform an MRI scan. If unpleasant sensations occur, turn off stimulation immediately. Package or component damage. Warn patients to seek medical guidance before entering environments that could adversely affect the operation of the implanted device, including areas protected by a warning notice preventing entry by patients fitted with a pacemaker. This can result in component damage, lead dislodgement, skin erosion, or stimulation at the implant site. Confirm that no adverse conditions to MR scanning are present. Safety for use of external defibrillator discharges on a patient receiving neurostimulation has not been established. For CT procedures in which the medical device is in or immediately adjacent to the programmed scan range, the operator should: If practical, try to move external devices out of the scan range. Do not place the IPG deeper than 4.0 cm (1.57 in) because the clinician programmer or patient controller may not communicate effectively with the IPG. Use caution when securing the soft tissue anchor because damage to the anchor or lead can occur and result in failure of the system. Sources of therapeutic radiation include therapeutic X rays, cobalt machines, and linear accelerators. To prevent injury or damage to the system, do not modify the equipment. Electromagnetic interference (EMI). However, current data shows that most patients using BurstDR stimulation therapy do not experience paresthesia. away from the generator and avoid placing any smart device in a pocket near the generator. Safety Topic / Subject Spinal Cord Stimulation (SCS) Systems, Abbott and St. Jude Medical. 72750 MAT-2215018 v2.0 | Item approved for U.S. use only. Patients using therapy that generates paresthesia should turn off stimulation before operating motorized vehicles, such as automobiles, or potentially dangerous machinery and equipment because sudden stimulation changes may distract them from properly operating it. This assessment should consider both the risk of depression and suicide as well as the potential clinical benefits of DBS therapy for the condition being treated. Mobile phones. Safety and effectiveness of neurostimulation for pediatric use have not been established. The operation of the clinician programmer or patient controller could cause them to ignite, causing severe burns, injury, or death. Removing components. For complete guidance, directions, and cautions on MRI safety with a specific device,please review the MRI procedure clinician's manual. Placing the IPG. Approved models and implant locations for an MR Conditional full system, *The IPG port plug associated with these models is also an MR Conditional component. PDF View Shellock R & D Services, Inc. email: . External defibrillators. 71409MAT-2116350 v4.0 | Item approved for U.S. use only. Device modification. To avoid the risk of skin erosion, implant components at the appropriate depth and inform patients to avoid touching their skin where components are implanted. Patients should be advised to keep their mobile phones and smart watches at least 15 cm (6 in.) Use extreme care when handling system components prior to implantation. If they must go through a gate or doorway containing this type of device, patients should turn off their generator and proceed with caution, being sure to move through the device quickly. Stimulation at high outputs may cause unpleasant sensations or motor disturbances, or render the patient incapable of controlling the stimulator. IPGs contain batteries as well as other potentially hazardous materials. Stimulation at high outputs may cause unpleasant sensations or motor disturbances or may render the patient incapable of controlling the patient controller. Schu S, Gulve A, ElDabe S, et al. Nerve damage may result from traumatic or surgical nerve injury. Implantation at vertebral levels above T10. Exposure to body fluids or saline. INTENDED USE This neurostimulation system is designed to deliver low-intensity electrical impulses to nerve structures. Do not use a clinician programmer or patient controller around explosive or flammable gas fumes or vapors. A multicenter, prospective trial to assess the safety and performance of the spinal modulation dorsal root ganglion neurostimulator system in the treatment of chronic pain. Avoid programming either device in a unipolar mode (using the devices can as an anode) or using neurostimulation system settings that interfere with the function of the implantable cardiac system. To minimize or prevent the implanted cardiac system from sensing the output of the neurostimulation system: Other active implanted devices. Wireless use restrictions. Postural changes. After defibrillation, confirm the neurostimulation system is still working. The U.S. Food and Drug Administration (FDA) approved Abbott's Eterna spinal cord stimulation (SCS) system for the treatment of chronic pain This neuromodulation device provides an optimized experience with the ability to wirelessly charge as few as five times per year, the lowest recharge burden compared to other rechargeable SCS systems 1,2,3 These patients should not climb ladders or participate in activities where postural changes or abrupt movements could alter the perception of stimulation intensity and cause patients to fall or lose control of equipment or vehicles or injure others. Abbott recently received new FDA-approved labeling which expands MRI compatibility with the leads used on the Proclaim TM XR Spinal Cord Stimulation System. Patients who failed to receive effective pain relief during trial stimulation are contraindicated to process to the permanent implant procedure. If needed, return the equipment to Abbott Medical for service. Conditional 5. Follow proper infection control procedures. Deep brain stimulation complications include, but are not limited to, the following: Undesirable changes in stimulation related to cellular changes in tissue around the electrodes, changes in the electrode position, loose electrical connections, or lead fracture, Loss of therapeutic benefit as a result of change in electrode positions, loose electrical connections, or lead or extension fracture, Initial jolt or tingling during stimulation; jolting or shocking sensations, Lead fracture, migration, or dislodgement, Extension malfunction, fracture, or disconnect, Deep brain stimulation system failure or battery failure within the device, Deep brain stimulation system malfunction or dislodgement, Allergic or rejection response to implanted materials, Persistent pain, tightness, or redness at the incision sites or general pain, General erosion or local skin erosion over the IPG, Persistent pain, tightness, or discomfort around the implanted parts (e.g., along the extension path in the neck), Impaired wound healing (e.g., incision site drainage) or abscess formation, Additional neurosurgical procedure to manage one of the above complications or to replace a malfunctioning component, Stimulation-related complications or other complications, Worsening of motor impairment and Parkinsons disease symptoms including dyskinesia, rigidity, akinesia or bradykinesia, myoclonus, motor fluctuations, abnormal gait or incoordination, ataxia, tremor, and dysphasia, Paresis, asthenia, hemiplegia, or hemiparesis, Sensory disturbance or impairment including neuropathy, neuralgia, sensory deficit, headache, and hearing and visual disturbance, Speech or language impairment including, aphasia, dysphagia, dysarthria, and hypophonia, Cognitive impairment including attention deficit, confusion, disorientation, abnormal thinking, hallucinations, amnesia, delusions, dementia, inability to act or make decisions, psychic akinesia, long term memory impairment, psychiatric disturbances, depression, irritability or fatigue, mania or hypomania, psychosis, aggression, emotional lability, sleep disturbance, anxiety, apathy, drowsiness, alteration of mentation, postural instability and disequilibrium, Cardiac dysfunction (e.g., hypotension, heart rate changes, or syncope), Eye disorder including eye apraxia or blepharospasm, (1) The symbol statement Rx only or only or the statement Caution: Federal law restricts this device to sale by or on the order of a ___, the blank to be filled with the word physician, dentist, veterinarian, or with the descriptive designation of any other practitioner licensed by the law of the State in which the practitioner practices to use or order the use of the device; and. Electrocardiograms. Keep dry to avoid damage. Application modification. In some environments, the use of wireless functions (for example, Bluetooth wireless technology) may be restricted.